P0136 and P0156 Fault Codes on 1999 Ford Taurus SE 3.0L DOHC: Downstream O2 Sensor Diagnosis
My 1999 Ford Taurus SE 3.0L DOHC vehicle has been throwing out fault codes P0136 and P0156, indicating issues with both downstream oxygen (O2) sensors. When connected to a data logger, the Bank 1 sensors show normal voltage readings within expected ranges. However, both Bank 2 downstream O2 sensors remain stuck at 0 mV, showing no signal variation. I'm wondering if a failure in either or both of the Bank 2 sensors could trigger codes for both downstream O2 sensors. What is the most effective diagnostic approach to identify the root cause?
Start with a detailed wiring diagram and use a digital multimeter (DVOM) to check continuity and voltage at each sensor connector. It's highly unlikely that both downstream O2 sensors would fail simultaneously.