2010 Audi A4 code p0016
I got this code about a month ago I replaced the cam shaft and crank shaft sensor car ran ok then the code came up again the car stalled and wouldn’t start a mechanic said it was the timing chain I had the timing work done got the car back running but the low oil pressure light came up then went away . I decided to plug my diagnostics tool in and p0016 came up again. Any suggestions would be greatly appreciated. I cleared the code and let the car run for a while then checked again and the same code came up.
might start with a oil pressure check - use a mechanical gauge for true pressure. VCT utilizes oil pressure to move cam. A scanner to check Cam to crank correlation. Double check the cam timing is correct.