Air Conditioning System — system
Fault codes
B133413 - B133413 Refrigerant Temperature Sensor 2 Open Circuit
1 cases
B133511 - B133511 Refrigerant Temperature Sensor 2 Short to Ground
1 cases
B133613 - B133613 Refrigerant Temperature Sensor 3 Open Circuit
1 cases
B133711 - B133711 Refrigerant Temperature Sensor 3 Short to Ground
1 cases
B133800 - B133800 Solenoid Valve 1 Status Fault
1 cases
B133900 - B133900 Solenoid Valve 2 Status Fault
1 cases
B133A00 - B133A00 Solenoid Valve 3 Status Fault
1 cases
B133B00 - B133B00 Solenoid Valve 4 Status Fault
1 cases
B133C00 - B133C00 Solenoid Valve 5 Status Fault
1 cases
B133D00 - B133D00 Solenoid Valve 6 Status Fault
1 cases
B133E00 - B133E00 Low Voltage PTC Relay 1 Fault
1 cases
B133F00 - B133F00 Low Voltage PTC Relay 2 Fault
1 cases
B134000 - B134000 Low Voltage PTC Relay 3 Fault
1 cases
B134111 - B134111 3-Way Water Valve Motor Short to Ground or Open Circuit
1 cases
B134211 - B134211 3-Way Water Valve Motor Short to Power
1 cases
B134392 - B134392 3-Way Water Valve Motor Positioning Error
1 cases
B134611 - B134611 Refrigerant Temperature Sensor 1 Short to Ground
1 cases
B134613 - B134613 Refrigerant Temperature Sensor 1 Open Circuit
1 cases
B134711 - B134711 AC Pressure Sensor Short to Power
1 cases
B134713 - B134713 AC Pressure Sensor Open Circuit
1 cases
B1CAF00 - B1CAF00 Humidity Sensor Fault
1 cases
B2A0801 - B2A0801 Evaporator Outlet Refrigerant Pressure Sensor Short to Power
1 cases
B2A0803 - B2A0803 Evaporator Outlet Refrigerant Pressure Sensor Open Circuit
1 cases
B2A0811 - B2A0811 Evaporator Outlet Refrigerant Temperature Sensor Short to Ground
1 cases
B2A0813 - B2A0813 Evaporator Outlet Refrigerant Temperature Sensor Open Circuit
1 cases
B2A2013 - B2A2013 Interior Temperature Sensor Open Circuit
1 cases
B2A2111 - B2A2111 Interior Temperature Sensor Short to Ground
1 cases
B2A2213 - B2A2213 Exterior Temperature Sensor Open Circuit
1 cases
B2A2311 - B2A2311 Exterior Temperature Sensor Short to Ground
1 cases
B2A2413 - B2A2413 Evaporator Temperature Sensor Open Circuit
1 cases
B2A2511 - B2A2511 Evaporator Temperature Sensor Short to Ground
1 cases
B2A2712 - B2A2712 Sun Sensor Short to Power
1 cases
B2A2A12 - B2A2A12 Mode Motor Short to Power
1 cases
B2A2A14 - B2A2A14 Mode Motor Short to Ground or Open Circuit
1 cases
B2A2A92 - B2A2A92 Mode Motor Did Not Reach Position
1 cases
B2A2B12 - B2A2B12 Temperature Blend Motor Short to Power
1 cases
B2A2B14 - B2A2B14 Temperature Blend Motor Short to Ground or Open Circuit
1 cases
B2A2B92 - B2A2B92 Temperature Blend Motor Did Not Reach Position
1 cases
B2A2F09 - B2A2F09 AC Piping in High Pressure State or Low Pressure State
1 cases
B2A3214 - B2A3214 Front Blower Motor Short to Ground or Open Circuit
1 cases
B2A3314 - B2A3314 Front Blower Adjustment Signal Short to Ground or Open Circuit
1 cases
B2A4B12 - B2A4B12 Recirculation Motor Short to Power
1 cases
B2A4B14 - B2A4B14 Recirculation Motor Short to Ground or Open Circuit
1 cases
B2A4B92 - B2A4B92 Recirculation Motor Did Not Reach Position
1 cases
B2A5811 - B2A5811 Driver Face Vent Outlet Temperature Sensor Short to Ground
1 cases
B2A5813 - B2A5813 Driver Face Vent Outlet Temperature Sensor Open Circuit
1 cases
B2A5913 - B2A5913 Driver Foot Vent Outlet Temperature Sensor Open Circuit
1 cases
B2AD616 - B2AD616 12V Power Supply Undervoltage (Below 9V)
1 cases
B2AD617 - B2AD617 12V Power Supply Overvoltage
1 cases
U025387 - U025387 Lost Communication with Compressor
1 cases
U02B087 - U02B087 Loss of Communication with Humidity Sensor
1 cases